info@universallab.org
WhatsApp: +41762172997
logo-header
​
logo
Material Testing
Mechanical Testing
Tensile TestFibre Tensile TestHardness TestImpact TestFatigue TestOthers
Thermal Testing
Thermomechanical AnalysisDSCTGATGA (TG-DSC, TG-DTA)
Surface, Coating and Corrosion
Adhesion TestScratch TestCorrosion Cycle Test
Physical Properties
Functional propertiesPorosityDensity
Elemental & Chemical Composition
Compositional analysisElemental analysis
Microscopic Characterization
Particle analysisMicroscopy
Product Testing
Food & Agriculture Testing
Consumer Goods Testing
Electronics & Electrical Testing
Medical & Pharmaceutical Testing
Automotive & Transportation Testing
Packaging & Materials Testing
Chemical & Hazardous Substances Testing
Semiconductor Testing
Battery Testing
Petrochemical Testing
Environmental Test
Water Testing
Drinking Water Analysis
Soil & Sediment Testing
Soil Chemistry (pH, Nutrients)
Air Testing
Particulate Matter (PM2.5, PM10)
Noise & Acoustic Testing
Industrial/Occupational Noise
Waste & Sludge Testing
Hazardous Waste Classification
Instrumental Test
Spectroscopy
Emission
XRFXPSICP-OESGD-OES
Absorption
FTIRUV/VIS/NIRAAS
Mass Spectrometry
SIMSICP-MS
Other
RamanNMR
Microscopy
Electron
SEMTEMEBSDEMPA
Other
AFMFIB
Mechanical
Volumetric
Tensile TestFibre Tensile TestImpact TestFatigue Test
Surface
HardnessNanoindentationScratch
Others
Thermal Analysis
TGADSC
Physical Analysis
BETLaser diffractionDensityContact AngleZeta potential
Chromatography
GCHPLCIC
Services
  • Applications
  • Techniques
  • Standards
  • Industries
Regulatory testing
  • PFAS
  • REACH
  • VOC
Environmental testing
  • Water
  • Gas
Data analysis
  • XRD
  • XPS
  • FTIR
  • Raman
  • NMR
  • CT
  • SIMS
  • TGA
Blog
  • Knowledge
  • News
  • Policy
  • About us
    Contact
    Published on
    Friday, March 22, 2024

    Introduction to Spectrum Analysis

    Authors
    • avatar
      Name
      Universallab
      Twitter
      @universallab

    After obtaining the diffraction spectrum on the X-ray diffractometer, it is important for beginners to understand how to interpret the spectrum and the significance of each feature in the spectrum. First, let's examine a simulated X-ray spectrum and use it to explain the meaning of spectral peaks.

    fig1
    Figure 1: Interpretation of spectral peaks

    Peak position, peak width, and peak intensity can be referred to as the three main elements of an X-ray diffraction spectrum. For the analysis of peak position, we primarily rely on Bragg's Law: 2dsinθ=nλ. For conventional diffractometers, copper targets are commonly used, with a wavelength approximately equal to 0.154 nm. The wavelength varies with the target material, and each target material has corresponding characteristics for X-ray wavelength and excitation voltage, as outlined below:

    fig2
    Figure 2: The wavelength and excitation voltage of characteristic X-rays

    The d-value represents the interplanar spacing of crystal planes. Each crystalline substance has a unit cell, and various crystal planes constitute a three-dimensional crystalline structure. Consequently, each crystalline substance exhibits a characteristic diffraction spectrum. By analyzing the spectrum obtained from X-ray diffractometry, we can determine the composition of a material. When external factors, such as doping, solid solution, stress changes, relaxation, defects, etc., alter the unit cell and cause changes in crystal plane spacing, the positions of diffraction peaks shift accordingly. Analyzing such peak shifts allows us to draw conclusions and verify whether material modification has been successful.

    Peak width is generally measured using the full width at half maximum (FWHM). In software, it is commonly abbreviated as FWHM. Peak width can be used to analyze material crystallinity, grain size, etc. For example, in the testing of lithium iron phosphate materials in the field of batteries, the FWHM of peaks is a key parameter for assessing material quality. In the semiconductor field, for epitaxially grown single crystal films, we can obtain the FWHM parameter by measuring the rocking curve, thereby evaluating the crystalline quality of the single crystal film. When a broadening, also known as a "breadloaf" peak, appears, as indicated by the pink portion in the figure above, we can determine the presence of amorphous components or uncrystallized substances in the material.

    Peak intensity generally refers to the area under the peak and is used to analyze the content of materials. After performing full-profile fitting and structural refinement on the tested spectrum, we can obtain the content of each phase in a mixed-phase material. This quantitative analysis method is more reliable than semi-quantitative methods such as the RIR method. By correlating the integrated intensity of the peak area with material content, we can not only perform quantitative analysis but also analyze crystallinity.

    Through the analysis of diffraction peak position, width, and intensity, we can thoroughly examine materials. Future updates will continue to explore the applications of X-ray diffraction in various fields and analyze materials from a fundamental perspective.

    Discuss on LinkedIn

    Tags

    ← Back to the blog
    HomeCategoryCart
    logo-footer-shop1

    European material analytical and measuring service provider dedicated for academic and industrial research

    About Us
    CareersTerms & ConditionsPrivacy Policy
    Customer Services
    Help CenterBecome a partnerReturns & Refunds
    Contact Us

    Parkstrasse 1, 5234 Villigen, Switzerland

    Email: info@universallab.org

    Phone: +41 762172997

    VAT: CHE-265.266.739 MWST

    © 2026 By Universallab. All rights reserved.

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.